| Specifications |
|
Item |
Specification |
|
|
Model |
Display Audio 2.0 |
|
|
Power supply |
DC 14.4V |
|
|
Parasitic current |
Max. 1mA (Head unit only) |
|
|
Antenna |
80PF 75Ω |
|
|
Tuning type |
PLL synthesized type |
|
|
Frequency range / Channel space |
FM |
87.5 - 108.0 MHz / 100 KHz |
|
AM |
531 - 1602 KHz / 9 KHz |
|
Component Location 1. Audio unit 2. Tweeter speaker 3. Roof antenna (Radio) 4. Front door speaker 5. Rear door speaker 6.
Description and operation Description The mode control actuator is located at the heater unit. It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level →
Repair procedures Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.